TYPE/HEIGHT OF BUILDING LOCATION REQUIREMENTS
PRIVATE BUILDINGS
Buildings above fifty (50) meters in height
At least 3 accelerographs located at:
1. Ground Floor / Lowest Basement
2. Middle Floor, and 4. Floor Below Roof
ERI in compliance with this IRR
Hospitals with fifty (50) bed capacity or more and schools
with twenty  (20) classrooms or more but not less than 3 storeys
One accelerographs installed at the
Ground Floor / Lowest Basement
ERI in compliance with this IRR
Commercial buildings with occupancy of at least 1,000 persons
or gross floor area of at least  10,000 square meters.
One accelerographs installed at the
Ground Floor / Lowest Basement
ERI in compliance with this IRR
Industrial buildings with occupancy of at least 1,000 persons
or gross floor area of at least  10,000 square meters.
One accelerographs installed at the
Ground Floor / Lowest Basement
ERI in compliance with this IRR